Home > ON Line UPS Systems > >
ELECTRA - 31-- Series
Technical Specification
Model: ELECTRA - 31---
Rating: 3 KVA to 40 KVA
Account Input: 300VAC to 480VAC
Frequency: 45 to 55Hz
DC Voltage: 192 to 360VDC
Charging Time: 8 Hours
Charging Type: Float Boost
Inverter
Technology: PWM-IGBT
Output Voltage: 220 / 230VAC
Voltage Regulation: +/-1%
Label 50Hz
Wave Form Pure Sine Wave
Harmonic Distortion< <3%
Inverter Efficency >90%
Power Factor 0.8 lag to unity
Overload 125% for 10 Min.
Create Factor 3:1
Phase Displacement
Transient Recovery within one cycle
Audible Noise <50db
Metering
Microprocessorbased DigitalLCD Meter for All Parameter
General
Dimensions (LxWxH)mm
Operating temperature 0-50°C
Humidity 95%
Protection
Protection standard
Indication
Mains on LED
Inverter on LED
DC Low LED + Buzzer
Fault LED + Buzzer
Output Overload LED + Buzzer
Mains fail LED
By Pass Facility
Manual Bypass Switch Provided
Static Bypass Switch Optional
Home > ON Line UPS Systems > >
10 KVA ON Line UPS
Technical Specification
Model: ELECTRA -3110
Rating: 10 KVA
Account Input: 300 -450VAC
Frequency: 50 Hz +/- 10%
DC Voltage: 192 to 360 VDC
Charging Time: 8 to 10 hours
Charging Type: IGBT based Float Boost Charger
Inverter
Technology: PWM - IGBT
Output Voltage: 230VAC
Voltage Regulation: +/-1%
Label 50Hz +/-0.5Hz
Wave Form Sine Wave
Harmonic Distortion< <3% for Linear Loads and <5% for Non-Linear Loads
Inverter Efficency 90%
Power Factor 0.8 to Unity
Overload 125% for 10 Min. & 150% for 1 Min.
Create Factor 3 : 1
Phase Displacement
Transient Recovery with 40 ms
Audible Noise <55db
Metering
Microprocessorbased DigitalLCD Meter LCD Display with LED indications
General
Dimensions (LxWxH)mm
Operating temperature anmient to 40 deg
Humidity 95 RH
Protection
Protection Over Load
Indication
Mains on
Inverter on
DC Low
Fault
Output Overload
Mains fail
By Pass Facility
Manual Bypass Switch Rotary
Static Bypass Switch OPTIONAL
Home > ON Line UPS Systems > >
UPS for ATM
Technical Specification
Model: HERMES-1101
Rating: 1.0 KVA
Account Input: 65 to 300VAC
Frequency: 45 to 55 Hz
DC Voltage: 48VDC
Charging Time: 08 Hrs
Charging Type: Float Boost
Inverter
Technology: PWM-IGBT
Output Voltage: 230VAC
Voltage Regulation: 1%
Label 50Hz
Wave Form Pure Sine
Harmonic Distortion< <3%
Inverter Efficency >90%
Power Factor .8
Overload 150%
Create Factor 3:1
Phase Displacement
Transient Recovery
Audible Noise <50db
Metering
Microprocessorbased DigitalLCD Meter YES
General
Dimensions (LxWxH)mm
Operating temperature
Humidity
Protection
Protection
Indication
Mains on YES
Inverter on YES
DC Low YES
Fault YES
Output Overload YES
Mains fail YES
By Pass Facility
Manual Bypass Switch YES
Static Bypass Switch OPTIONAL